{"product_id":"havells-tpn-c-curve-mcb-32a-triple-pole-neutral-6ka-dhmxctnz032","title":"Havells TPN C Curve MCB 32A Triple Pole with Neutral DHMXCTNZ032 | 6kA Overload \u0026 Short Circuit Protection","description":"\u003ch2\u003eHavells 32A TPN C Curve MCB\u003c\/h2\u003e\u003cp\u003eThe Havells TPN C Curve MCB is designed for reliable circuit protection in residential, commercial, and light industrial electrical distribution systems. With triple pole with neutral execution, 6kA short circuit breaking capacity, flame-retardant thermoplastic material, and C Curve tripping, it helps protect three-phase circuits from overload and short circuit faults, including motor and inductive load applications.\u003c\/p\u003e\u003ch3\u003eKey Features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e32A TPN MCB suitable for low voltage three-phase circuit protection.\u003c\/li\u003e\n\u003cli\u003eTriple pole with neutral execution for three-phase distribution systems.\u003c\/li\u003e\n\u003cli\u003eC Curve tripping characteristic suitable for motor and inductive load applications.\u003c\/li\u003e\n\u003cli\u003e6kA rated short circuit breaking capacity for dependable fault protection.\u003c\/li\u003e\n\u003cli\u003eFlame-retardant thermoplastic material for improved electrical safety.\u003c\/li\u003e\n\u003cli\u003eHammer trip mechanism for reliable tripping performance.\u003c\/li\u003e\n\u003cli\u003eLine and load interchangeability for flexible installation.\u003c\/li\u003e\n\u003cli\u003eDesigned as per IS\/IEC 60898-1 standard.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHavells\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eMCB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eDHMXCTNZ032\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Rating\u003c\/td\u003e\n\u003ctd\u003e32A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eTriple Pole with Neutral\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurve\u003c\/td\u003e\n\u003ctd\u003eC Curve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Frequency\u003c\/td\u003e\n\u003ctd\u003e50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Voltage\u003c\/td\u003e\n\u003ctd\u003e240V AC \/ 415V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Insulation Voltage\u003c\/td\u003e\n\u003ctd\u003e690V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Impulse Voltage\u003c\/td\u003e\n\u003ctd\u003e4kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Short Circuit Breaking Capacity\u003c\/td\u003e\n\u003ctd\u003e6kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Capacity\u003c\/td\u003e\n\u003ctd\u003e25 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-5°C to 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003e35 mm x 7.5 mm DIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Position\u003c\/td\u003e\n\u003ctd\u003eVertical \/ Horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTightening Torque\u003c\/td\u003e\n\u003ctd\u003e2 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e84 mm x 60.2 mm x 17.7 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eIndia\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Contents\u003c\/td\u003e\n\u003ctd\u003e1 Main Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eResidential three-phase distribution boards\u003c\/li\u003e\n\u003cli\u003eCommercial electrical panels\u003c\/li\u003e\n\u003cli\u003eMotor and inductive load protection\u003c\/li\u003e\n\u003cli\u003eTPN circuit protection applications\u003c\/li\u003e\n\u003cli\u003eOverload and short circuit protection in low voltage systems\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhy Buy From MGCkart\u003c\/h3\u003e\u003cp\u003eMGCkart helps buyers source genuine branded electrical products with structured technical information, reliable supply support, and product clarity for residential, commercial, and project-based electrical requirements.\u003c\/p\u003e","brand":"Havells Store","offers":[{"title":"Default Title","offer_id":44417237188650,"sku":"DHMXCTNZ032","price":1039.0,"currency_code":"INR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0590\/1837\/9306\/files\/fhvvehuwht06_42__7.jpg?v=1780491588","url":"https:\/\/www.mgckart.in\/products\/havells-tpn-c-curve-mcb-32a-triple-pole-neutral-6ka-dhmxctnz032","provider":"MGCKART","version":"1.0","type":"link"}